Featured calculator
Predicting wine alcohol from must sugar is more than a single number: the instrument reading needs correcting for temperature and alcohol, the sugar-to-alcohol conversion factor depends on fermentation conditions, and every measurement has an error. This calculator takes all three into account and gives the prediction as a range.
SG ↔ Brix: SG = 1 + Bx/(258.6 − 227.1·Bx/258.2); Oechsle = (SG − 1)·1000; Baumé = 145·(1 − 1/SG). Hydrometer readings are corrected to 20 °C by the ratio of water densities. Sugar ≈ 10·Bx·SG − non-sugar extract (usually 20–30 g/L in grape must). The range is computed by Monte Carlo (3000 trials): instrument error, non-sugar extract ±5 g/L and the factor ±0.3 g/L. The EU 16.83 is a conventional factor for labelling and law; real fermentations usually give 16.5–18.
Ethanol raises the refractive index, so during fermentation a refractometer "overstates" the sugar. The correction uses Terrill's cubic formula (S. Terrill, 2011): FG = 1 − 0.0044993·OB + 0.011774·CB + 0.00027581·OB² − 0.0012717·CB² − 0.00000728·OB³ + 0.000063293·CB³ (Brix values divided by the WCF). The formula was developed for beer wort; for grape must (≥ 20 °Bx) it is approximate, so check the final result with a hydrometer. Alcohol ≈ (OG − SG)·131.25.
Adding sugar (chaptalisation): sucrose gives 1.053 g of hexose per gram and increases volume by ~0.62 L/kg. Lowering: blending with a low-sugar must (the calculator assumes such a must at 16 °Bx). Adding water to grape must is prohibited in the EU and many countries, and chaptalisation is restricted by law; see the "Wine law" and "Sugar correction" pages.
The overall equation of alcoholic fermentation (Gay-Lussac):
$$\mathrm{C_6H_{12}O_6 \rightarrow 2\,C_2H_5OH + 2\,CO_2}$$
180 g of hexose theoretically gives 92 g of ethanol, i.e. 0.511 g/g. Ethanol has a density of 0.789 g/mL, so 1% vol of alcohol theoretically needs 7.89/0.511 ≈ 15.4 g/L of sugar. In reality yeast spends part of the sugar on glycerol, organic acids, biomass and other by-products, and part of the ethanol evaporates with the CO₂. So the practical factor is 16.5–18 g/L per percent:
• controlled, cool white fermentation: ~16.5–17;
• red fermentation with a cap, warm, in an open vessel: 17.5–18 (more evaporation and biomass).
EU legislation calculates potential alcohol with a conventional factor of 16.83 g/L per percent. This is a legal convention, not a physical constant.
Must sugar is measured with two instruments:
1. A refractometer measures the refractive index and shows the result in °Brix (mass percent of sucrose). It needs only a few drops, and good instruments have automatic temperature compensation.
2. A hydrometer measures density: as SG (relative to water), °Oechsle or °Baumé. It is temperature-sensitive and usually calibrated at 20 °C.
The units are related as follows:
$$SG = 1 + \frac{Bx}{258.6 - 227.1\cdot Bx/258.2},\qquad {}^\circ Oe = (SG-1)\cdot 1000,\qquad {}^\circ Bé = 145\left(1 - \frac{1}{SG}\right)$$
Brix is not all sugar: grape must contains 20–30 g/L of non-sugar soluble solids (acids, salts, phenolics, nitrogen compounds). So sugar is estimated as:
$$S\ [\text{g/L}] \approx 10\cdot Bx\cdot SG - N$$
where N is the non-sugar extract. For exact sugar, laboratory analysis (OIV methods) or the OIV tables are needed.
Warm liquid is expanded, so a hydrometer sinks deeper into it and shows a lower density. The calculator corrects the reading to 20 °C by the ratio of water densities:
$$SG_{20} = SG_T\cdot\frac{\rho_w(20)}{\rho_w(T)}$$
At 30 °C this is ~+0.0025, i.e. ~0.6 °Bx or ~0.35% of potential alcohol. A sugar solution expands slightly more than water, and the instrument's glass also expands; for an exact correction use the manufacturer's table or a sample cooled to 20 °C.
During fermentation ethanol appears in the solution, and its refractive index is higher than that of water. So a refractometer overstates the sugar: a dry wine with almost no sugar left can read 6–8 °Bx. The true density is estimated from the original (OB) and current (CB) readings together. The best known is Sean Terrill's cubic formula:
$$SG = 1 - 0.0044993\,OB + 0.011774\,CB + 0.00027581\,OB^2 - 0.0012717\,CB^2 - 0.0000072800\,OB^3 + 0.000063293\,CB^3$$
The formula was developed from experimental data on beer wort; for grape must, especially above 20 °Bx, it is approximate. So check the result with a hydrometer at the end of fermentation. If the refractometer is slightly off compared with the hydrometer, it can be calibrated with the WCF (dividing the Brix by it).
The prediction error has three sources: instrument error (analogue refractometer ~±0.2 °Bx, hydrometer ~±0.001 SG), the unknown amount of non-sugar extract, and the conversion factor. The calculator combines them by Monte Carlo: it randomly varies each input within its error 3000 times and builds the distribution of the prediction. The 95% range is usually ±0.6–1.0%: this is the real precision with which alcohol can be predicted from must.
If the potential alcohol is below the target, sugar (sucrose) is added. On hydrolysis 1 kg of sucrose gives 1.053 kg of hexose and increases the must volume by ~0.62 L:
$$m = \frac{(S_t - S)\cdot V}{1053 - 0.62\,S_t}\ \text{kg}$$
If the alcohol would be too high, it is lowered by blending with a low-sugar must. Adding water to grape must is prohibited in the EU and many countries, and chaptalisation is restricted by law (see "Sugar correction" and "Wine law").
R. B. Boulton, V. L. Singleton, L. F. Bisson, R. E. Kunkee, Principles and Practices of Winemaking (Springer, 1996); P. Ribéreau-Gayon et al., Handbook of Enology, vol. 1 (Wiley); OIV, Compendium of International Methods of Analysis: Alcoholic strength, Density, Sugars; Commission Delegated Regulation (EU) 2019/934 (calculation of potential alcohol, 16.83 g/L); S. Terrill, Refractometer FG results (seanterrill.com, 2011); G. S. Kell, density of water 0–150 °C (J. Chem. Eng. Data, 1975). The uncertainty values for non-sugar extract and the factor are illustrative.
1. In the "Prediction" mode, choose the instrument and unit, enter the reading and the instrument error, and for a hydrometer also the sample temperature. Set the non-sugar extract (usually 25 g/L) and the factor that matches the fermentation type. The cards show the density at 20 °C (in all units), sugar, potential alcohol and the 95% range, and the histogram shows the distribution of the prediction.
2. In the "Fermentation progress" mode, enter the original Brix (before fermentation) and the current refractometer reading to get the true density, the alcohol already formed, fermentation progress and the expected final alcohol.
3. In the "Adjustment" mode, enter the must volume, Brix and desired alcohol to get the sugar to add or the amount of low-sugar must to blend.
• Refractometer 22.0 °Bx, ±0.2 → SG 1.092, sugar ~215 g/L, 12.7% (95%: 11.9–13.5).
• Hydrometer 1.090 at 30 °C → 1.0928 at 20 °C, 0.0028 above the reading.
• Original 22 °Bx, current 11 °Bx → true SG ~1.017, alcohol already ~9.9%, fermentation ~77% complete.
• 100 L of 19 °Bx must, target 12.5% → ~3.5 kg of sucrose.
• Calibrate the refractometer with distilled water (0 °Bx) every time.
• Strain the must sample and remove bubbles: grape particles and CO₂ both distort the readings of either instrument.
• Make the prediction from an average sample of the whole vessel: sugar can differ by several °Bx between bunches (see "Sugars and must density", sample size).
• At the end of fermentation do not trust the refractometer: use a hydrometer.
1. Why can a refractometer reading not be used directly during fermentation?
A refractometer is calibrated on sugar solutions. During fermentation ethanol appears, which bends light more strongly than water, so the reading is higher than the true value. Using the original and current Brix together (e.g. with Terrill's formula) gives an estimate of the true density.
2. What does the EU 16.83 g/L mean?
16.83 g/L of must sugar = 1% vol of potential alcohol is a legal convention. The real yield depends on yeast, temperature, evaporation and biomass.
3. A hydrometer calibrated at 20 °C reads 1.090 at 30 °C. The true density is:
Warm liquid is expanded and less dense, so the hydrometer sinks deeper and reads lower. When corrected to 20 °C the density rises by ~0.003.