Home cellar · practical guide
How much sugar is in the must and how much is left during fermentation, how much acid the wine has, what its pH is, how much SO₂ protects it, and whether the malolactic fermentation has finished. How to measure correctly with home tools and how to read the result.
A refractometer measures the bending of light, a hydrometer measures density. Before fermentation both give the same result. Once fermentation starts, alcohol distorts the refractometer reading and it shows too much sugar, so during fermentation the reading is corrected using the starting sugar (Terrill formula, accuracy ≈ ±0.003). Sugar g/L = 10 × Brix × SG × 0.9; potential alcohol = sugar ÷ 16.83.
Acidity = NaOH (mL) × N × 75.04 ÷ sample (mL), expressed as tartaric acid (g/L). Divide by 1.531 to convert to sulphuric acid. A pH meter is checked with two buffers: an ideal electrode has a slope of 100%. The titration curve on the chart is calculated with a model of the wine acids (tartaric, malic, citric) and potassium, fitted to your acidity and pH.
Free SO₂ (mg/L) = iodine (mL) × N × 32 000 ÷ sample (mL). With 0.02 N iodine and a 25 mL sample, each mL of iodine = 25.6 mg/L. Only molecular SO₂ protects the wine, and its share depends on pH: molecular = free ÷ (1 + 10^(pH − 1.81)). Potassium metabisulphite (K₂S₂O₅) yields 57.6% SO₂. In red wine the Ripper method reads 5–10 mg/L high because of phenolics.
Rf = spot distance ÷ solvent front distance, both from the start line, to the centre of the spot. In butanol–formic acid–water solvent typical Rf values are: tartaric ≈ 0.28, citric ≈ 0.42, malic ≈ 0.51, lactic ≈ 0.69. Rf depends on temperature and paper, so it is best to run a malic acid standard alongside; the scale is then corrected to it.
Wine can be made by eye and by taste, but a few simple measurements prevent many mistakes. Sugar content tells you when to pick and how much alcohol the wine will have. Specific gravity during fermentation tells you whether fermentation is running or has stopped. Acidity and pH determine the taste, the colour and how well the wine is protected from microbes. Measuring SO₂ tells you whether the protection is sufficient, and a chromatogram shows whether the malolactic fermentation has finished.
For a home cellar the following are enough: a refractometer, a hydrometer with a measuring cylinder, a thermometer, a pH meter or pH paper, an acidity titration kit, an SO₂ kit and, if you wish, a paper chromatography kit.
| Instrument | What it measures | When it is used | Where to buy |
|---|---|---|---|
| Refractometer | Sugar content (°Brix) from one drop | Ripeness checks in the vineyard, must | Winemaking supply shop, online |
| Hydrometer + cylinder | Specific gravity (SG) or a sugar scale | Must, fermentation monitoring | Winemaking supply shop |
| Thermometer | Temperature | With every measurement, fermentation | Hardware shop, pharmacy |
| pH meter, buffers | pH | Must, wine, SO₂ dose calculation | Laboratory supplier, online |
| Titration kit | Titratable acidity | Must, wine | Winemaking supply or chemical reagent shop |
| SO₂ kit (iodine) | Free and total SO₂ | After fermentation, in storage | Winemaking supply shop |
| Chromatography kit | Wine acids | Monitoring malolactic fermentation | Winemaking supply shop, online |
A refractometer measures the angle by which light bends: the more sugar dissolved in a liquid, the more the light is deflected. The scale is graduated in °Brix: 1 °Brix means 1 gram of sucrose in 100 grams of solution. Grape must also contains other dissolved substances besides sugar (acids, minerals), so the real sugar is about 10% less than the value calculated from Brix.
The advantage of a refractometer is that it needs only one drop: pick 100 berries in the vineyard, crush them and measure the juice. To measure correctly:
• At the start of each season calibrate it with distilled water: the reading should be 0. If it is not, adjust it with the screw.
• Put the drop on the prism with no air bubble; close the plate and wait 30 seconds for the temperature to even out.
• If the refractometer has no ATC (automatic temperature compensation), each degree above 20 °C lowers the reading by ≈ 0.075 °Brix, and this must be added back.
• After measuring, wipe the prism with water and dry it with a soft cloth.
Once fermentation has started, a refractometer no longer measures sugar correctly: alcohol has a higher refractive index than water and raises the reading. In a dry wine with almost no sugar left the refractometer still shows 5–8 °Brix. If the starting sugar is known, the current specific gravity can be estimated with an empirical formula (Terrill):
$$SG \approx 1 - 0.0044993\,B_0 + 0.011774\,B + 0.00027581\,B_0^2 - 0.0012717\,B^2 - 0.00000728\,B_0^3 + 0.000063293\,B^3$$
where $B_0$ is the starting and $B$ the current reading (°Brix). The formula was developed for beer and is approximate for wine (±0.003). At the end of fermentation confirm the result with a hydrometer.
A hydrometer is a glass float that sinks deeper the lower the density of the liquid. In water it reads 1.000, in ripe grape must 1.090–1.110, in dry wine 0.990–0.996 (alcohol is lighter than water). Some hydrometers also have a sugar scale (°Brix or °Oe), some a potential alcohol scale.
Specific gravity and sugar content are related as follows:
$$SG = 1 + \frac{B}{258.6 - 0.8796\,B}\qquad S\ (\text{g/L}) \approx 10 \cdot B \cdot SG \cdot 0.9$$
Potential alcohol (% vol) = sugar (g/L) ÷ 16.83. This is the official factor in European legislation; at home wine often gives slightly less alcohol.
To measure correctly:
• Pour the must or wine into a clear cylinder (250 mL), lower the hydrometer in and spin it gently to shake off bubbles. During fermentation CO₂ bubbles lift the hydrometer, so shake the sample well first.
• Read at the level of the liquid surface, with your eye level with the surface, not at the edge of the meniscus.
• A hydrometer is calibrated at a given temperature (usually 20 °C, sometimes 15.6 °C). Warm must expands and reads low: at 30 °C by ≈ 0.0026, about 0.7 °Brix. The correction uses the ratio of water densities:
$$SG_{20} = SG_{T}\cdot\frac{\rho_w(20\ °C)}{\rho_w(T)}$$
• Do not return the sample to the vessel: it may have been contaminated. Wash the cylinder and hydrometer before and after use.
The end of fermentation is confirmed by two readings: if the SG has not changed in three days and is below 0.996, the wine is dry. If the SG stops above 1.000, fermentation has stuck, which is a problem (see Chapter III).
There are two different measures of acidity. Titratable acidity shows how much acid the wine contains in total; it determines how sour it tastes. pH shows how strong that acidity is, that is, how many free hydrogen ions there are. pH determines colour stability, the effectiveness of SO₂ and the growth of bacteria. Two wines with the same acidity can have different pH: potassium, which the vine takes up from the soil, partly neutralises the acids and raises the pH.
Titratable acidity is measured with alkali (NaOH): NaOH of known strength is added drop by drop to a wine sample until the indicator changes colour or the pH meter shows the end point:
$$TA\ (\text{g/L as tartaric}) = \frac{V_{NaOH}\cdot N \cdot 75.04}{V_{\text{sample}}}$$
In Europe (OIV) the end point is pH 7.0 (indicator bromothymol blue: yellow → blue-green); in the USA it is pH 8.2 (phenolphthalein: colourless → pink). Titrating to 8.2 gives a little more: phosphate, amino acids and phenolics are neutralised in that range. Older Georgian and Russian literature often expresses acidity as tartaric acid, French literature as sulphuric acid (a number 1.531 times smaller).
In red and amber wine the colour change of the indicator is hard to see. Dilute such wine 4–5 times with water before titrating or, better, find the end point with a pH meter.
| Parameter | White wine | Red, amber |
|---|---|---|
| Titratable acidity, g/L as tartaric | 5.5–8 | 4.5–6.5 |
| pH | 3.1–3.4 | 3.3–3.7 |
A pH meter measures the voltage of a glass electrode. The electrode ages over time, so calibrate it with two buffers (pH 4.00 and 7.00) on every day you measure. An ideal electrode has a slope of 100% (59.2 mV per pH unit at 25 °C). If the slope is below 95%, clean the electrode; if it is below 90%, replace it. Always keep the electrode in storage solution (3M KCl), never in distilled water or dry. pH paper is too coarse for wine (±0.3).
SO₂ exists in wine in two forms: free and bound (to acetaldehyde, sugars, anthocyanins). Only free SO₂ protects the wine, and of that only the molecular form, whose share depends on pH:
$$SO_2^{\text{mol}} = \frac{SO_2^{\text{free}}}{1 + 10^{\,pH - 1.81}}$$
At pH 3.2 ≈ 4% of free SO₂ is molecular, at pH 3.7 only ≈ 1.3%. A white wine needs ≈ 0.8 mg/L molecular SO₂ to be protected, a red ≈ 0.5 mg/L (tannins and anthocyanins add protection). A high-pH wine therefore needs much more SO₂.
At home SO₂ is measured with iodine (the Ripper method). Iodine oxidises SO₂; once all the free SO₂ has been oxidised, the excess iodine turns blue with starch:
$$SO_2\ (\text{mg/L}) = \frac{V_{I_2}\cdot N\cdot 32\,000}{V_{\text{sample}}}$$
Sulphuric acid is first added to the sample (to lower its pH), then starch. For total SO₂ the sample is first left with NaOH for 10 minutes, which releases the bound SO₂. The method is quick and cheap, but in red wine phenolics and ascorbic acid also consume iodine, so the result is 5–10 mg/L high and the colour change is hard to see. For an accurate measurement there is the aeration-oxidation method (in a laboratory).
Potassium metabisulphite (K₂S₂O₅) yields 57.6% SO₂: 1 gram in 100 litres of wine adds ≈ 5.8 mg/L SO₂. Part of the added SO₂ binds immediately, so measure again 1–2 days after an addition.
During malolactic fermentation bacteria convert malic acid into lactic acid. Whether this process has finished is easiest to see with paper chromatography. On chromatography paper a start line is drawn in pencil 2.5 cm from the bottom edge, and small drops are applied on it with a capillary: the wine and acid standards (tartaric, malic, lactic). The paper is rolled into a cylinder and stood in a jar with 1 cm of solvent at the bottom (butanol, formic acid, water and the indicator bromocresol green).
The solvent rises up the paper and carries the acids with it, each at a different speed. After 6–8 hours, when the solvent nears the top edge, the paper is taken out, the front is marked and the paper is dried. The indicator colours the background blue-green, and the acids show as yellow spots. The relative distance of each spot is:
$$R_f = \frac{\text{spot distance from start}}{\text{front distance from start}}$$
Typical Rf values: tartaric ≈ 0.28, citric ≈ 0.42, malic ≈ 0.51, lactic ≈ 0.69. If the malic acid spot has disappeared from the wine lane, the malolactic fermentation is complete. The method is qualitative: less than 0.1–0.2 g/L of malic acid no longer shows on paper.
The solvent has a strong smell and is flammable: work outdoors or in a well-ventilated room, with gloves, away from flames. Keep the jar tightly closed.
Home instruments will not give laboratory accuracy, but they are enough to manage a wine: sugar ±0.2 °Brix, SG ±0.001, pH ±0.05 (with a calibrated electrode), acidity ±0.2 g/L, SO₂ ±5 mg/L. The main thing is always to measure the same way and to write down the result, with the date, temperature and vessel number. The trend is often more important than the exact number of a single reading. Use the journal on the "From grape to wine" page for your records.
Some measurements cannot be done at home or are inaccurate: exact alcohol content (a vinometer gives only a rough estimate, and only in dry wine), volatile acidity, the exact residual sugar, protein and tartrate stability. If you sell your wine or enter it in a competition, send a sample to an accredited laboratory.
1. In the "Sugar" mode choose the instrument (refractometer or hydrometer) and when you are measuring: before or during fermentation. Enter the reading and the sample temperature. Before fermentation you get the corrected sugar content, specific gravity, sugar in g/L and potential alcohol. The chart shows how much to add to the reading at different temperatures.
2. During fermentation enter the starting sugar as well. You will see the current specific gravity, how much of the sugar has fermented, how much alcohol is already in the wine and how much sugar is left. The chart shows how the SG and the refractometer reading change as fermentation proceeds: you will see that even in a dry wine the refractometer shows 5–8 °Brix.
3. In the "Acidity and pH" mode enter the titration data: sample volume, NaOH strength and the NaOH used. Below, enter the pH meter readings in the two buffers and in the wine: you get the electrode slope and the corrected pH. The chart shows the titration curve and the colour change point of both indicators.
4. In the "SO₂" mode enter the iodine titration data, the wine's pH and type, and the vessel volume. You will see the free, total and molecular SO₂ and how many grams of potassium metabisulphite to add.
5. In the "Chromatography" mode enter the solvent front distance and the distances of the spots in the wine lane (cm, from the start line to the centre of the spot). If you also ran a malic acid standard, enter its spot distance too. You will see which acids are in the wine and whether the malolactic fermentation has finished.
Everything you enter is kept in your browser, so it will still be there when you come back to the page.
• 2–3 weeks before harvest, once a week: sugar with the refractometer (100 berries from different parts of the vineyard), and acidity and pH if you wish.
• On crushing day: sugar with the hydrometer, acidity, pH. From these the doses of SO₂ and, if needed, sugar or acid are calculated.
• During fermentation, once a day at the same time: specific gravity and temperature. Write them in the journal.
• At the end of fermentation: SG twice, 3 days apart. If it does not change and is below 0.996, fermentation is complete.
• During malolactic fermentation: a chromatogram every 2–3 weeks.
• After fermentation and in storage: free SO₂ at every racking and every 1–2 months; pH once, after the malolactic fermentation.
• Take the must sample from the middle depth of the vessel after stirring well: the top layer and the liquid under the pomace cap are different.
• During fermentation shake the sample or pour it back and forth before measuring, so the CO₂ escapes.
• A cloudy sample can be cleared with filter paper or by letting it settle; this matters especially for the refractometer and for iodometry.
• NaOH absorbs CO₂ from the air and loses strength: keep it tightly closed and renew it every year. Keep the iodine solution in dark glass in a cool place; old, faded iodine gives a wrong result.
• NaOH and sulphuric acid burn skin and eyes: work with goggles and gloves, away from children.
• Rinse the pH electrode with distilled water between buffers and before putting it in the wine, and dab it dry gently; do not rub it.
• Never return a measured sample to the vessel.
1. On the fifth day of fermentation a refractometer reads 9 °Brix. Does this mean ≈ 90 g/L of sugar is left in the wine?
Alcohol has a higher refractive index than water. If fermentation started at 22 °Brix, 9 °Brix on the refractometer corresponds to an SG of ≈ 1.006, so much less sugar is left.
2. A hydrometer is calibrated at 20 °C and the must is at 30 °C. What happens if you do not correct the reading?
At 30 °C the must expands and its density falls: the hydrometer reads ≈ 0.0026 low, about 0.7 °Brix.
3. Two wines have the same free SO₂, 30 mg/L, but one has pH 3.2 and the other pH 3.7. Which is better protected?
The molecular share of SO₂ changes about threefold for every 0.5 pH units: at pH 3.2, 30 mg/L free gives ≈ 1.2 mg/L molecular; at pH 3.7 only ≈ 0.4 mg/L.
4. On the chromatogram the malic acid spot has disappeared from the wine lane and the lactic acid spot is clear. What does it mean?
During malolactic fermentation bacteria convert malic acid into lactic acid. When the malic acid has gone, MLF is complete, and the wine can be racked and protected with SO₂.